Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzcan, Ali
dc.contributor.authorİlkbas, Salih
dc.date.accessioned2019-10-20T09:13:38Z
dc.date.available2019-10-20T09:13:38Z
dc.date.issued2015
dc.identifier.issn0003-2670
dc.identifier.issn1873-4324
dc.identifier.urihttps://dx.doi.org/10.1016/j.aca.2015.08.015
dc.identifier.urihttps://hdl.handle.net/11421/17002
dc.descriptionWOS: 000361646800033en_US
dc.descriptionPubMed ID: 26388392en_US
dc.description.abstractIn this study, we have performed the preparation of over-oxidized poly(3,4-ethylenedioxythiophene) nanofibers modified pencil graphite electrode (Ox-PEDOT-nf/PGE) to develop a selective and sensitive voltammetric uric acid (UA) sensor. It was noted that the over-oxidation potential and time had a prominent effect on the UA response of the Ox-PEDOT-nf/PGE. Characterizations of PEDOT-nf/PGE and Ox-PEDOT-nf/PGE have been performed by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The highest voltammetric response of UA was obtained at pH 2.0. A linear relationship between the concentration of UA and oxidation peak currents was observed in the concentration range of 0.01-20.0 mu M. The detection limit (1.3 nM according to S/N = 3) and reproducibility (RSD: 4.6 % for N: 10) have also been determined. The effects of different substances on the determination of UA have been investigated. A very high peak separation value of 423 mV was obtained between UA and ascorbic acid which is the major interfering substance for UA. The use of Ox-PEDOT-nf/PGE has been successfully tested in the determination of UA in human blood serum and urine samples for the first time in the literatureen_US
dc.description.sponsorshipAnadolu University Scientific Research Projects Commission [1306F114, 1404F143]en_US
dc.description.sponsorshipFinancial support of Anadolu University Scientific Research Projects Commission (Project No: 1306F114 and 1404F143) is gratefully acknowledged.en_US
dc.language.isoengen_US
dc.publisherElsevier Science BVen_US
dc.relation.isversionof10.1016/j.aca.2015.08.015en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectUric Aciden_US
dc.subjectAscorbic Aciden_US
dc.subjectPoly(3,4-Ethylenedioxythiophene)en_US
dc.subjectOver-Oxidationen_US
dc.subjectBlood Serumen_US
dc.subjectUrineen_US
dc.titlePreparation of poly(3,4-ethylenedioxythiophene) nanofibers modified pencil graphite electrode and investigation of over-oxidation conditions for the selective and sensitive determination of uric acid in body fluidsen_US
dc.typearticleen_US
dc.relation.journalAnalytica Chimica Actaen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume891en_US
dc.identifier.startpage312en_US
dc.identifier.endpage320en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorÖzcan, Ali


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster