Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorEmir Diltemiz, Sibel
dc.contributor.authorHür, Deniz
dc.contributor.authorErsöz, Arzu
dc.contributor.authorDenizli, Adil
dc.contributor.authorSay, Rıdvan
dc.date.accessioned2019-10-20T14:27:47Z
dc.date.available2019-10-20T14:27:47Z
dc.date.issued2009
dc.identifier.issn0956-5663
dc.identifier.urihttps://dx.doi.org/10.1016/j.bios.2009.01.032
dc.identifier.urihttps://hdl.handle.net/11421/17825
dc.descriptionWOS: 000271931900011en_US
dc.descriptionPubMed ID: 19250816en_US
dc.description.abstractQuartz crystal microbalance (QCM) sensors coated with molecular imprinted polymers (MIP) have been developed for the determination of thymine. In this method, methacryloylamidoadenine (MA-Ade) have used as a new monomer and thymine template for inspiration of DNA nucleobases interaction. The thymine can be simultaneously hydrogen binding to MA-Ade and fit into the shape-selective cavities. Thus, the interaction between nucleobases has an effect on the binding ability of the QCM sensors. The binding affinity of the thymine imprinted sensors has investigated by using the Langmuir isotherm. The thymine imprinted QCM electrodes have shown homogeneous binding sites for thymine (K(a): 1.0 x 10(5) M(-1)) while heterogeneous binding sites for uracil. On the other hand, recognition selectivity of the QCM sensor based on thymine imprinted polymer toward to uracil, ssDNA and ssRNA has been reported in this worken_US
dc.description.sponsorshipAnadolu Universityen_US
dc.description.sponsorshipThis work has dedicated to the 50th anniversary of Anadolu University.en_US
dc.language.isoengen_US
dc.publisherElsevier Advanced Technologyen_US
dc.relation.isversionof10.1016/j.bios.2009.01.032en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMolecular Imprinting Polymers (Mip)en_US
dc.subjectQuartz Crystal Microbalance (Qcm)en_US
dc.subjectThymineen_US
dc.subjectDnaen_US
dc.subjectThymine Imprinted Sensorsen_US
dc.titleDesigning of MIP based QCM sensor having thymine recognition sites based on biomimicking DNA approachen_US
dc.typearticleen_US
dc.relation.journalBiosensors & Bioelectronicsen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Kimya Bölümüen_US
dc.identifier.volume25en_US
dc.identifier.issue3en_US
dc.identifier.startpage599en_US
dc.identifier.endpage603en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.contributor.institutionauthorEmir Diltemiz, Sibel
dc.contributor.institutionauthorHür, Deniz
dc.contributor.institutionauthorErsöz, Arzu
dc.contributor.institutionauthorSay, Rıdvan


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster