dc.description.abstractThe systems in which energy is most intensely used in airport terminal buildings are HVAC systems. More efficient heating and cooling systems and the performance of the building envelope can provide significant reductions in energy consumption without compromising comfort conditions in terminal buildings. In this study, the exterior walls of the International Hasan Polatkan Airport were examined using a thermal camera, and it was observed that heat losses were due to the lack of thermal insulation. The optimum insulation thicknesses for different thermal insulation materials (EPS, XPS, glass wool and stone wool) were determined by the life cycle cost (LCC) method. The effect of the application of the calculated insulation thicknesses on energy performance and the economic payback periods were determined. As a result, optimum insulation thicknesses have been found as 0.05 m, 0.033 m, 0.078 m and 0.973 m for EPS, XPS, glass wool and stone wool in respective order. It was observed from the results of analysis that the economic payback period changed between 4.85 and 7.7 years if optimum insulation thicknesses are applied.en_US
dc.description.sponsorshipAnadolu University Scientific Research Projects Commission [1604F143]en_US
dc.description.sponsorshipThis study was supported by the Anadolu University Scientific Research Projects Commission under Grant No. 1604F143.en_US
dc.language.isoengen_US
dc.publisherInderscience Enterprises LTDen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOptimum Insulation Thicknessen_US
dc.subjectLife Cycle Costen_US
dc.subjectLccen_US
dc.subjectEnergyen_US
dc.subjectAirporten_US
dc.titleDetermination of optimum insulation thickness for building's walls with respect to different insulation materials: a case study of International Hasan Polatkan Airport terminalen_US
dc.typearticleen_US
dc.relation.journalInternational Journal of Sustainable Aviationen_US
dc.contributor.departmentAnadolu Üniversitesi, Havacılık ve Uzay Bilimleri Fakültesi, Uçak Gövde Motor Bakım Bölümüen_US
dc.identifier.volume4en_US
dc.identifier.issue2en_US
dc.identifier.startpage147en_US
dc.identifier.endpage161en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US]