Ara
Toplam kayıt 2236, listelenen: 81-90
Bioassays on Periploca graeca L. (Silk vine)
(1998)
Silk vine, Periploca graeca L. (Asclepiadaceae) which is a poisonous plant, was collected in July 1997 from Eskisehir (Asagi Kuplu-Mayislar Village). The methanolic extracts of the air dried leaves and twigs were separately ...
Alizarin and purpurin contents of Rubia tinctorum L. roots collected from various regions of Turkey [Turkiye'nin degisik yorelerinden toplanan Rubia tinctorum L. koklerinde alizarin ve purpurin miktarlari]
(1999)
The effect of extraction method on the recovery of alizarin and purpurin from roots of Rubia tinctorum L. was investigated. Alizarin and purpurin contents in Turkish Madder collected from various regions of Anatolia have ...
Aconitum orientale alkaloids
(Akademiya Nauk Uzbekskoi Ssr, 1994)
…
The determination of caffeine in tea infusion by second-order derivative ultraviolet spectroscopy
(1992)
[No abstract available]
Inhibitory effects of carvacrol on DMBA induced pulmonary tumorigenesis in rats
(1998)
Essential oils of various plant species rich in carvacrol have several ethnomedical uses for various diseases in Turkey. Carvacrol, which was obtained by fractional distillation of Origanun onites L essential oil was tested ...
Supercritical CO2 extraction of volatile components from leaves of Laurus nobilis L.
(Akademiya Nauk Uzbekskoi Ssr, 1998)
Comparative investigation of the chemical compositions of volatile components from leaves of Laurus nobilis obtained by the supercritical CO2 extraction and the hydro- and seam distillation was carried out.
Some 1-substituted 3-aryl-1,4-dihydro-1,2,4-triazino[4,3-a]- benzimidazoles and their vasodilatory activities
(Societa Chimica Italiana, 1997)
In this study, some 1-substituted 3-aryl-1,4-dihydro-1,2,4- triazino[4,3-a]benzimidazole derivatives were synthesized, their structures were elucidated, and their vasodilatory activities were examined. It was found that ...
TLC densitometric determination of omeprazole in pharmaceutical preparations
(Govi-Verlag GMBH, 1998)
…
Modified consolidation test apparatus
(International Society Offshore& Polar Engineers, 1999)
Consolidation test is conducted in the laboratory by oedometer test equipment. Load is applied step by step with mechanical weights in this test. The load is kept for 24 hours in each step. Sample disturbance takes place ...
Effects of Mass-Transfer and Hydrogen Pressure on the Fixed-Bed Pyrolysis of Sunflower Bagasse
(American Chemical Society, 1994)
…