dc.contributor.authorDejmkova, Hana
dc.contributor.authorDağ, Candan
dc.contributor.authorBarek, Jiri
dc.contributor.authorZima, Jiri
dc.date.accessioned2019-10-20T09:03:13Z
dc.date.available2019-10-20T09:03:13Z
dc.date.issued2012
dc.identifier.issn1895-1066
dc.identifier.urihttps://dx.doi.org/10.2478/s11532-012-0056-8
dc.identifier.urihttps://hdl.handle.net/11421/16659
dc.descriptionWOS: 000304618900035en_US
dc.description.abstractNew methods for the determination of metoclopramide, antiemetic and gastroprokinetic pharmaceutical, were developed, using differential pulse voltammetry (DPV) and flow injection analysis (FIA) with amperometric detection on a boron-doped diamond film electrode. Electrode pretreatment necessary to ensure the stable results was investigated and it was found, that while DPV requires frequent electrode cleaning, FIA with a sufficiently high flow rate can maintain a stable signal with no signs of electrode passivation. The calculated quantification limits of the DPV and FIA with amperometric detection were 0.13 mu mol L-1 and 0.015 mmol L-1, respectively. The applicability of the new methods was verified by the determination of metoclopramide in a pharmaceutical preparation. FIA with amperometic detection proved to be sensitive, accurate and, due to the resistance of the electrode to the passivation, also simple to handle.en_US
dc.description.sponsorshipCzech Ministry of Education, Youth and Sports [MSM 0021620857]; Charles University in Prague [SVV 2012-265201, UNCE 2012/44]; Grant Agency of the Czech Republic [P206/12/G151]; Technology Agency of the Czech Republic [TA01020565]en_US
dc.description.sponsorshipFinancial support of the Czech Ministry of Education, Youth and Sports (project no. MSM 0021620857), of Charles University in Prague (projects no. SVV 2012-265201 and UNCE 2012/44), of the Grant Agency of the Czech Republic (project no. P206/12/G151) and of the Technology Agency of the Czech Republic (project no. TA01020565) is gratefully acknowledged.en_US
dc.language.isoengen_US
dc.publisherVersitaen_US
dc.relation.isversionof10.2478/s11532-012-0056-8en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMetoclopramideen_US
dc.subjectDifferential Pulse Voltammetryen_US
dc.subjectFlow Injection Analysisen_US
dc.subjectBoron-Doped Diamond Film Electrodeen_US
dc.subjectPassivationen_US
dc.titleVoltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrodeen_US
dc.typearticleen_US
dc.relation.journalCentral European Journal of Chemistryen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume10en_US
dc.identifier.issue4en_US
dc.identifier.startpage1310en_US
dc.identifier.endpage1317en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US