dc.contributor.author | Dejmkova, Hana | |
dc.contributor.author | Dağ, Candan | |
dc.contributor.author | Barek, Jiri | |
dc.contributor.author | Zima, Jiri | |
dc.date.accessioned | 2019-10-20T09:03:13Z | |
dc.date.available | 2019-10-20T09:03:13Z | |
dc.date.issued | 2012 | |
dc.identifier.issn | 1895-1066 | |
dc.identifier.uri | https://dx.doi.org/10.2478/s11532-012-0056-8 | |
dc.identifier.uri | https://hdl.handle.net/11421/16659 | |
dc.description | WOS: 000304618900035 | en_US |
dc.description.abstract | New methods for the determination of metoclopramide, antiemetic and gastroprokinetic pharmaceutical, were developed, using differential pulse voltammetry (DPV) and flow injection analysis (FIA) with amperometric detection on a boron-doped diamond film electrode. Electrode pretreatment necessary to ensure the stable results was investigated and it was found, that while DPV requires frequent electrode cleaning, FIA with a sufficiently high flow rate can maintain a stable signal with no signs of electrode passivation. The calculated quantification limits of the DPV and FIA with amperometric detection were 0.13 mu mol L-1 and 0.015 mmol L-1, respectively. The applicability of the new methods was verified by the determination of metoclopramide in a pharmaceutical preparation. FIA with amperometic detection proved to be sensitive, accurate and, due to the resistance of the electrode to the passivation, also simple to handle. | en_US |
dc.description.sponsorship | Czech Ministry of Education, Youth and Sports [MSM 0021620857]; Charles University in Prague [SVV 2012-265201, UNCE 2012/44]; Grant Agency of the Czech Republic [P206/12/G151]; Technology Agency of the Czech Republic [TA01020565] | en_US |
dc.description.sponsorship | Financial support of the Czech Ministry of Education, Youth and Sports (project no. MSM 0021620857), of Charles University in Prague (projects no. SVV 2012-265201 and UNCE 2012/44), of the Grant Agency of the Czech Republic (project no. P206/12/G151) and of the Technology Agency of the Czech Republic (project no. TA01020565) is gratefully acknowledged. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Versita | en_US |
dc.relation.isversionof | 10.2478/s11532-012-0056-8 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Metoclopramide | en_US |
dc.subject | Differential Pulse Voltammetry | en_US |
dc.subject | Flow Injection Analysis | en_US |
dc.subject | Boron-Doped Diamond Film Electrode | en_US |
dc.subject | Passivation | en_US |
dc.title | Voltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrode | en_US |
dc.type | article | en_US |
dc.relation.journal | Central European Journal of Chemistry | en_US |
dc.contributor.department | Anadolu Üniversitesi, Fen Fakültesi, Fizik Bölümü | en_US |
dc.identifier.volume | 10 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 1310 | en_US |
dc.identifier.endpage | 1317 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |