dc.contributor.author | Ersöz, Arzu | |
dc.contributor.author | Emir Diltemiz, Sibel | |
dc.contributor.author | Özcan, A. Atılır | |
dc.contributor.author | Denizli, Adil | |
dc.contributor.author | Say, Rıdvan | |
dc.date.accessioned | 2019-10-20T09:13:18Z | |
dc.date.available | 2019-10-20T09:13:18Z | |
dc.date.issued | 2008 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.uri | https://dx.doi.org/10.1016/j.bios.2008.06.058 | |
dc.identifier.uri | https://hdl.handle.net/11421/16820 | |
dc.description | WOS: 000261262000037 | en_US |
dc.description | PubMed ID: 18718752 | en_US |
dc.description.abstract | Recently, the 8-hydroxy-2'-deoxyguanosine (8-OHdG) has been used as a marker to determine the oxidative stress. There is no any cheap and easy determination method based on chips and sensor systems for the determination of 8-OHdG. In this study, we have proposed imprinting methods for 8-OHdG recognition and determination using methacryloylamidohistidine-platinum(II) [MAH-Pt(II)] as a new metal-chelating monomer. The study includes the solid-phase extraction (SPE) of blood sample by a new 8-OHdG imprinted sorbent and the measurement of binding interaction of 8-OHdG imprinted quartz crystal microbalance (QCM) sensor via ligand interaction. 8-OHdG imprinted sorbent has prepared by bulk polymerization of MAH-Pt(II) and N-N'-methylenebisacrylamide, 8-OHdG imprinted sensor has prepared on a QCM chip coating the thiol pretreated Au electrode. At the end of these steps, a thin molecular imprinted polymer (MIP) film for the detection of 8-OHdG has developed and analytical performance of QCM sensor which has prepared using MIP was investigated. The affinity constant (K.) for 8-OHdG using MAH-Pt-based thin film has determined by using the Scatchard method. The average percentage recovery of 8-OHdG from plasma samples was found as 80% by using of 8-OHdG imprinted SPE material. At the last step, 8-OHdG level in several blood plasma has been determined by this improved QCM sensor. The obtained results confirmed that the 8-OHdG level in cancer patient's blood was significantly higher than in general subjects | en_US |
dc.description.sponsorship | The Scientific and Technical Research Council of Turkey [TOBITAK-MAG-104M374] | en_US |
dc.description.sponsorship | This study was supported by "The Scientific and Technical Research Council of Turkey" (TOBITAK-MAG-104M374). Furthermore, it has dedicated to the 50th anniversary of Anadolu University. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Advanced Technology | en_US |
dc.relation.isversionof | 10.1016/j.bios.2008.06.058 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Molecularly Imprinted Polymer (Mip) | en_US |
dc.subject | Quartz Crystal Microbalance (Qcm) | en_US |
dc.subject | 8-Hydroxy-2'-Deoxyguanosine (S-Ohdg) | en_US |
dc.subject | Metal-Chelate Interaction | en_US |
dc.title | Synergie between molecular imprinted polymer based on solid-phase extraction and quartz crystal microbalance technique for 8-OHdG sensing | en_US |
dc.type | article | en_US |
dc.relation.journal | Biosensors & Bioelectronics | en_US |
dc.contributor.department | Anadolu Üniversitesi, Fen Fakültesi, Fizik Bölümü | en_US |
dc.identifier.volume | 24 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 742 | en_US |
dc.identifier.endpage | 747 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Ersöz, Arzu | |
dc.contributor.institutionauthor | Emir Diltemiz, Sibel | |
dc.contributor.institutionauthor | Say, Rıdvan | |