Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorTunçel, Muzaffer
dc.contributor.authorÖncü Kaya, Elif Mine
dc.contributor.authorUysal, Ülkü Dilek
dc.contributor.authorGüray, Tufan
dc.date.accessioned2019-10-20T09:13:35Z
dc.date.available2019-10-20T09:13:35Z
dc.date.issued2015
dc.identifier.issn1300-0527
dc.identifier.urihttps://dx.doi.org/10.3906/kim-1408-49
dc.identifier.urihttps://hdl.handle.net/11421/16980
dc.descriptionWOS: 000353336300015en_US
dc.description.abstractA validated liquid chromatography method employing a fluorescence detector for the determination of ochratoxin A (OTA) was developed with double internal standard and it was applied to ten different poultry feeds. The analysis was performed in an octadecyl silane column using a solvent system [ACN:water:formic acid (50:50:1.25, v/v/v)] by isocratic elution. The flow rate and injection volume were 1 mL min(-1) and 12 pi, respectively. Signals were detected at 278(lambda(ex))/315(lambda(em)) and 330(lambda(ex))/450(lambda(em)) nm between 0 and 8, and 8.01 and 20.0 min, respectively. The method was validated with precision, linearity, accuracy, limit of detection, limit of quantification, robustness, and stability. Good linearity (r(2) = 0.9998-0.9999) was achieved over a concentration range of 1.60 x 10(-8) M to 6.40 x 10(-6) M for OTA. LOD and LOQ values were 7.83 x 10(-1) M and 2.37 x 10(-9) M, and 2.01 x 10(-9) M and 6.10 x 10-9 M for internal standard 1 (IS1) and internal standard 2 (IS2), respectively, on an interday basis. The method was applied to poultry feed samples. Good recovery data ranged between 79.10% and 85.57%, and 71.98% and 76.66%, and the RSD% values were in the range of 1.36-11.70 and 2.07-2.34 for IS1 and IS2, respectively.en_US
dc.language.isoengen_US
dc.publisherScientific Technical Research Council Turkey-Tubitaken_US
dc.relation.isversionof10.3906/kim-1408-49en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnimal Feed And Poultry Feeden_US
dc.subjectFluorescence Detectoren_US
dc.subjectHplcen_US
dc.subjectMycotoxinen_US
dc.subjectOchratoxin Aen_US
dc.titleHPLC fluorescence determination of ochratoxin A utilizing a double internal standard and its application to poultry feeden_US
dc.typearticleen_US
dc.relation.journalTurkish Journal of Chemistryen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume39en_US
dc.identifier.issue2en_US
dc.identifier.startpage372en_US
dc.identifier.endpage381en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorTunçel, Muzaffer
dc.contributor.institutionauthorUysal, Ülkü Dilek


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster