Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzcan, Levent
dc.contributor.authorŞahin, Yücel
dc.contributor.authorTürk, Hayrettin
dc.date.accessioned2019-10-20T09:13:42Z
dc.date.available2019-10-20T09:13:42Z
dc.date.issued2008
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.urihttps://dx.doi.org/10.1016/j.bios.2008.05.004
dc.identifier.urihttps://hdl.handle.net/11421/17023
dc.descriptionWOS: 000261262000002en_US
dc.descriptionPubMed ID: 18599285en_US
dc.description.abstractAn enzymeless biosensor, based on electrode position of overoxidized polypyrrole nanofiber onto pencil graphite electrode and modified with cobalt(II) phthalocyanine tetrasulfonate (CoPcTS), was investigated in this study. CoPcTS showed electrocatalytic activity for the oxidation of glucose in alkaline solution. The electrochemical performance of the modified electrodes was investigated by differential pulse voltammetric (DPV) method. The resulting biosensor exhibited excellent performance for glucose determination with a wide linear range (0.25-20 mM), a highly reproducible response (R.S.D. of 2.7%), low percentage of the interferences and long-term stability. The calculated detection limit was 0.1 mM at 3 sigma. in order to verify the reliability of the biosensor, it was applied to the determination of glucose in serum samples. The results were satisfactory and agreed closely with those measured in a hospitalen_US
dc.description.sponsorshipAnadolu University Research Found [031064, 051060]en_US
dc.description.sponsorshipFinancial support of Anadolu University Research Found (Project Nos.: 031064 and 051060) is gratefully acknowledged. YS would like to thank Prof. Dr. Servet Turan and Res. Asst. Hilmi Yurdakul for taking the SEM pictures of the polymer films.en_US
dc.language.isoengen_US
dc.publisherElsevier Advanced Technologyen_US
dc.relation.isversionof10.1016/j.bios.2008.05.004en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOveroxidized Polypyrroleen_US
dc.subjectBiosensoren_US
dc.subjectCobalt(Ii) Phthalocyanineen_US
dc.subjectGlucoseen_US
dc.subjectElectrocatalysisen_US
dc.titleNon-enzymatic glucose biosensor based on overoxidized polypyrrole nanofiber electrode modified with cobalt(II) phthalocyanine tetrasulfonateen_US
dc.typearticleen_US
dc.relation.journalBiosensors & Bioelectronicsen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume24en_US
dc.identifier.issue4en_US
dc.identifier.startpage512en_US
dc.identifier.endpage517en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorŞahin, Yücel
dc.contributor.institutionauthorTürk, Hayrettin


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster