Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorŞahin, Mutlu
dc.contributor.authorŞahin, Yücel
dc.contributor.authorÖzcan, Adnan
dc.date.accessioned2019-10-20T09:13:45Z
dc.date.available2019-10-20T09:13:45Z
dc.date.issued2008
dc.identifier.issn0925-4005
dc.identifier.urihttps://dx.doi.org/10.1016/j.snb.2008.01.004
dc.identifier.urihttps://hdl.handle.net/11421/17045
dc.descriptionWOS: 000258011000002en_US
dc.description.abstractPolypyrrole (PPy) and overoxidized polypyrrole (OPPy) films were used as a potentiometric detector in ion chromatography, in order to determine some anions and cations in water samples. Electrodeposition of PPy film was performed by constant potential at +0.80V (vs. Ag/AgCl) in an aqueous solution containing 0.1 M pyrrole and 0.2 M sodium nitrate. The overoxidation of PPy film was carried out in 0.1 M NaOH solution by cycling the potential between +0.80 and +1.20V at 50mV s(-1). The PPy film exhibited good sensitivity toward, especially, fluoride and chloride ions. The lowest detection limit (3 sigma) observed was 10(-8) M for fluoride with PPy detector. This is the first study using OPPy electrode for the potentiometric detection of both monovalent and divalent cations in literature. The correlation coefficients obtained from the calibration curves were 0.947-0.991 for anions and 0.998-0.999 for cations. The response of ions at the PPy and OPPy electrodes maintained over 90-94% of the original value for 45 and 30 days, respectively. It can be concluded from the observed data that these electrodes can be used as an alternative detector materials to analyse anions and cations in the water samples by ion chromatographyen_US
dc.language.isoengen_US
dc.publisherElsevier Science Saen_US
dc.relation.isversionof10.1016/j.snb.2008.01.004en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPolypyrroleen_US
dc.subjectOveroxidized Polypyrroleen_US
dc.subjectPotentiometric Detectionen_US
dc.subjectIon Chromatographyen_US
dc.subjectWater Analysisen_US
dc.titleIon chromatography-potentiometric detection of inorganic anions and cations using polypyrrole and overoxidized polypyrrole electrodeen_US
dc.typearticleen_US
dc.relation.journalSensors and Actuators B-Chemicalen_US
dc.contributor.departmentAnadolu Üniversitesi, Fen Fakültesi, Fizik Bölümüen_US
dc.identifier.volume133en_US
dc.identifier.issue1en_US
dc.identifier.startpage5en_US
dc.identifier.endpage14en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorŞahin, Mutlu
dc.contributor.institutionauthorŞahin, Yücel
dc.contributor.institutionauthorÖzcan, Adnan


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster