Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDe Santis, F
dc.contributor.authorDöğeroğlu, T
dc.contributor.authorFino, A
dc.contributor.authorMenichelli, S
dc.contributor.authorVazzana, C
dc.contributor.authorAllegrini, I
dc.date.accessioned2019-10-21T20:11:25Z
dc.date.available2019-10-21T20:11:25Z
dc.date.issued2002
dc.identifier.issn1618-2642
dc.identifier.urihttps://dx.doi.org/10.1007/s00216-002-1368-x
dc.identifier.urihttps://hdl.handle.net/11421/20206
dc.descriptionWOS: 000177859200039en_US
dc.descriptionPubMed ID: 12240650en_US
dc.description.abstractDiffusive samplers for the determination of NOx and NO2 based on collection on a coated carbon paper filter have been developed. NO is first oxidized to NO2 and then collected on the reactive surface. When NO2 and NOx samplers are exposed simultaneously, NO can be calculated by difference. The sampler has been derived from a Palmes design as recently modified by Bertoni et al. for the determination of BTX (benzene, toluene, xylenes). Laboratory tests were conducted in controlled atmosphere to evaluate linearity, uptake rate, face velocity effects, sample stability, influence of relative humidity, precision and accuracy. The samplers are capable of reliable measurements of the two species at common levels of a polluted atmosphere in urban settings yielding average concentration levels over 1 month and beyond. The uptake rate of NO2 was found to be 11.7 mL/min in a very good agreement (within 5%) with the value calculated from theory. The measured uptake rate for NOx was determined in experiments involving sampling at different concentration levels in comparison to chemiluminescence (CL) measurements. The precision of the measurements for co-located passive samplers was better than 5%. The accuracy of the data collected is within 20% of the actual value measured by CL. The laboratory and field results show that the NOx and NO2 samplers meet the data quality goal requested by the first EU Directive 1999/30/ EU for these pollutants.en_US
dc.language.isoengen_US
dc.publisherSpringer-Verlag Berlinen_US
dc.relation.isversionof10.1007/s00216-002-1368-xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAtmospheric Pollutionen_US
dc.subjectDiffusive Samplingen_US
dc.subjectNitrogen Dioxideen_US
dc.subjectNitrogen Oxidesen_US
dc.titleLaboratory development and field evaluation of a new diffusive sampler to collect nitrogen oxides in the ambient airen_US
dc.typearticleen_US
dc.relation.journalAnalytical and Bioanalytical Chemistryen_US
dc.contributor.departmentAnadolu Üniversitesi, Mühendislik Fakültesi, Çevre Mühendisliği Bölümüen_US
dc.identifier.volume373en_US
dc.identifier.issue8en_US
dc.identifier.startpage901en_US
dc.identifier.endpage907en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster