Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorTombul, Mustafa
dc.contributor.authorKoparal, Ali Savaş
dc.contributor.authorÖğütveren, Ülker Bakır
dc.date.accessioned2019-10-21T21:11:35Z
dc.date.available2019-10-21T21:11:35Z
dc.date.issued2005
dc.identifier.issn1201-3080
dc.identifier.urihttps://hdl.handle.net/11421/21058
dc.descriptionWOS: 000234669100009en_US
dc.description.abstractContaminants can adhere to soil and subsequent rainfall can leach the adhered contaminant into groundwater. Transport models can determine the main features of contaminant and carrier transport in groundwater systems, and therefore determine potential risks for public health and ecosystems. In this study, the effect of copper contamination caused by a wood preservation plant near Eskis ehir, Turkey, on the possible pollution of drinking water supply wells was investigated with two different models. The first model, which deals with the movement of contaminants to groundwater, is a numerical model known as Flonet/Trans (Waterloo Hydrogeologic 1997). It has been used to investigate the change in contaminants from the source with respect to time and distance. The second model, which measures contaminant movement with respect to time and distance through simulations, is an analytical model known as Multi-Flow. It was used for verification of the first model. Both numerical and analytical models have been successfully applied at the work area for investigation of the effects of copper contamination in groundwater. Using the numerical model, the copper concentration in the first observation well was found to be 1.59 mg L-1, and using the analytical model, the copper concentration was found to be 1.35 mg L-1 after 550 days. The measured quantity was 2.11 mg L-1, thus the analytical model is best used for verification of results obtained by simulations of the numerical model.en_US
dc.language.isoengen_US
dc.publisherIwa Publishingen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGroundwateren_US
dc.subjectContaminant Transporten_US
dc.subjectWood Preservationen_US
dc.subjectTransportation Modelen_US
dc.subjectCopper Contaminationen_US
dc.titleTransport modelling of copper contamination in groundwater caused by a wood preservation planten_US
dc.typearticleen_US
dc.relation.journalWater Quality Research Journal of Canadaen_US
dc.contributor.departmentAnadolu Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.identifier.volume40en_US
dc.identifier.issue4en_US
dc.identifier.startpage469en_US
dc.identifier.endpage475en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorKoparal, Ali Savaş
dc.contributor.institutionauthorÖğütveren, Ülker Bakır


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster