dc.contributor.author | Öcal, Eren S. | |
dc.contributor.author | Kaytakoğlu, Süleyman | |
dc.date.accessioned | 2019-10-21T21:12:20Z | |
dc.date.available | 2019-10-21T21:12:20Z | |
dc.date.issued | 2005 | |
dc.identifier.issn | 1302-3160 | |
dc.identifier.uri | http://www.trdizin.gov.tr/publication/paper/detail/TlRBME1EYzM= | |
dc.identifier.uri | https://hdl.handle.net/11421/21345 | |
dc.description.abstract | Bu çalışmada, bir taşıyıcı gaz içerisindeki $SO_2$, sulu kalsiyum hidroksit $(Ca(OH)_2)$ süspansiyonları ile atmosferik basınçta çalışan bir kabarcıklı kolon reaktörde absorplanmıştır. Bu amaçla 3 L %7,5 CaO içeren sulu kalsiyum hidroksit süspansiyonu kullanılmıştır. Gaz derişimi ve gaz akış hızı sırasıyla hava içerisinde 4000, 6000, 8000 ve 10000 ppm $SO_2$ ve 15, 20, 25 ve 30 L/dk. olarak seçilmiştir. Absorpsiyon ortamının sıcaklığı 25 °C ve 50°C olarak alınmıştır. Absorpsiyon sırasında, sistemden atılan gazın $SO_2$ içeriği ve absorpsiyon ortamının pH değeri sürekli olarak ölçülmüştür. Ayrıca belirli sürelerde sistemden numuneler alınarak absorpsiyon ortamının kalsiyum iyonu $(Ca^{2+})$ içeriği belirlenmiştir. Yüksek gaz akış hızı ve yüksek $SO_2$ derişiminde sisteme aşırı SO2 yüklemesi olmuştur. Bu şartlarda, süspansiyonun $SO_2$ ile hızla doygunluğa ulaşması nedeniyle %100 $SO_2$ gideriminde kısa süreler elde edilmiştir. Ayrıca kabarcıklı ve püskürtmeli kolon reaktör arasında bir performans karşılaştırması yapılmıştır. Bu karşılaştırmada su içerisinde %7,5 CaO, 50°C sıcaklık ve 30 L gaz/dk. çalışma şartları olarak kullanılmıştır. Gaz derişimi 6500 ppm $SO_2$ in altında olduğu zaman kabarcıklı kolon reaktörde $SO_2$ gideriminin püskürtmeli kolon reaktöre göre daha etkin olduğu bulunmuştur. | en_US |
dc.description.abstract | In this study, $SO_2$ in a carrier gas was absorbed by aqueous calcium hydroxide $(Ca(OH)_2)$ suspension in a bubble column reactor working at atmospheric pressure. For this purpose 3 L of aqueous calcium hydroxide suspension involving %7,5 CaO was used. Gas compositions and flow rates were chosen as 4000, 6000, 8000, 10000 ppm $SO_2$ in air and 15, 20, 25, 30 L/min, respectively. The temperature of absorption medium was taken as 25 °C and 50°C. During absorption, the $SO_2$ content of the gas emitted from system and the pH value of the absorption medium were continuously measured. The calcium ion $(Ca^{2+})$ contents of the absorption medium were also determined by taking samples from the system at certain time intervals. Excessive $SO_2$ loading to the system was done at higher gas flow rate and higher $SO_2$ concentration. At these conditions, shorter times in 100% $SO_2$ removal were obtained due to quick saturation of suspension with $SO_2$. A performance comparison between bubble column reactor and spray column reactor was also done. In this comparison, 7.5 % CaO in water, 50°C temperature and 30 L gas /min were used as working conditions. It was found that $SO_2$ removal in bubble column reactor was more effective than spray column reactor when gas composition was lower than 6500 ppm SO2. | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Ortak Disiplinler | en_US |
dc.title | Kabarcıklı kolon reaktörde $Ca(OH)_2$ süspansiyonları ile $SO_2$ giderimi | en_US |
dc.title.alternative | $SO_2$ removal in a bubble column by aqueous $Ca(OH)_2$suspensions | en_US |
dc.type | other | en_US |
dc.relation.journal | Anadolu Üniversitesi Bilim ve Teknoloji Dergisi :A-Uygulamalı Bilimler ve Mühendislik | en_US |
dc.contributor.department | Anadolu Üniversitesi, Mühendislik Fakültesi, Kimya Mühendisliği Bölümü | en_US |
dc.identifier.volume | 6 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 209 | en_US |
dc.identifier.endpage | 217 | en_US |
dc.relation.publicationcategory | Diğer | en_US |
dc.contributor.institutionauthor | Kaytakoğlu, Süleyman | |