dc.contributor.author | Soyseven M. | |
dc.contributor.author | Aboul-Enein H.Y. | |
dc.contributor.author | Arli G. | |
dc.date.accessioned | 2020-07-09T20:55:05Z | |
dc.date.available | 2020-07-09T20:55:05Z | |
dc.date.issued | 2020 | |
dc.identifier.issn | 0950-5423 | |
dc.identifier.uri | https://doi.org/10.1111/ijfs.14661 | |
dc.identifier.uri | https://hdl.handle.net/11421/23859 | |
dc.description.abstract | An effective, simple and rapid analytical method using HPLC was developed for the analysis of monosodium glutamate (MSG) in various food samples obtained from local market in Turkey. The determination of MSG was performed by its derivatisation with o-phthaldialdehyde (OPA). A high-performance liquid chromatography-ultraviolet/diode array detection method was performed by using C18 (150 mm × 4.6 mm, 2.7 ?m) column with the mobile phase consisting of 10 mm phosphate buffer solution (pH = 5.90) and methanol (75:25, v/v). The applied method was optimised and the validated. The method was linear from 1 to 50 ?g mL?1 of MSG. The correlation coefficient value of the developed method was obtained as R2 = 0.9999. The limit of detection and limit of quantification limits were 0.015 and 0.050 ?g mL?1, respectively. MSG contents of the food samples range from 0.09 g kg?1 to 120.80 g kg?1. The validated method was successfully applied for the analysis of MSG in several food samples. © 2020 Institute of Food Science and Technology | en_US |
dc.description.sponsorship | Anadolu Ãœniversitesi | en_US |
dc.description.sponsorship | This research is supported by the Project No: 1507S562 of Anadolu University. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Blackwell Publishing Ltd | en_US |
dc.relation.isversionof | 10.1111/ijfs.14661 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | DAD | en_US |
dc.subject | food | en_US |
dc.subject | high-performance liquid chromatography | en_US |
dc.subject | monosodium glutamate | en_US |
dc.subject | o-phthaldialdehyde | en_US |
dc.subject | UV | en_US |
dc.title | Development of a HPLC method combined with ultraviolet/diode array detection for determination of monosodium glutamate in various food samples | en_US |
dc.type | article | en_US |
dc.relation.journal | International Journal of Food Science and Technology | en_US |
dc.contributor.department | Anadolu Üniversitesi | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |